Stoebich Conveyor System Closures
Fire Protection for conveyor techniques and conveyor system closures.
RGT
Conveyor Systems
- Separable conveyor systems
- Continuous belt conveyor spec sheet
- Continuous roller conveyor spec sheet
- Continuous chain conveyor spec sheet
- Continuous traveling carriages spec sheet
Fire Resistance: 3 hours fire rating and 90 min. insulation in accordance with German test standard (DIN 4102) and FM approval
Durability: 200,000 cycles
Proof of Usability: German approval (90 minutes insulation), FM approval (5’11” x 7’1″ (w x h))
ECClos-flex
Conveyor Systems
- Interrupted conveyor systems
- Separable conveyor systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
- Continuous traveling carriages
Fire Resistance: 120 min. fire rating with UL 10B listing (based on Stoebich Fire Curtain)
Proof of Usability: UL 10B listing (based on Stoebich Fire Curtain) engineering judgement is necessary
Universal-B
Conveyor Systems
- Interrupted conveyor systems
- Separable conveyor systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
- Continuous traveling carriages
- Sorter
- Newspaper Conveyor
Fire Resistance: 3 hours fire rating in accordance with British test standards (BS 476) and 90 min. insulation in accordance with German test standard (DIN 4102)
Durability: 200,000 cycles
Proof of Usability: German approval (90 minutes insulation), British test report engineering judgement is necessary.
ECClos-S
Conveyor Systems
- Interrupted conveyor systems
- Separable conveyor systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
- Continuous traveling carriages
Fire Resistance: 2 hours fire rating and 120 min. insulation in accordance with European test standard (EN 1366-7)
Durability: 200,000 cycles
Proof of Usability: European approval (ETA) (120 minutes insulation), CE marked engineering judgement is necessary
ECClos-Q
Conveyor Systems
- Separable conveyor systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
Fire Resistance: 4 hours fire rating and 120 min. insulation in accordance with European test standard (EN 1366-7)
Durability: 200,000 cycles
Proof of Usability: European approval (ETA) (120 minutes insulation), CE marked engineering judgement is necessary
ECClos-D
Conveyor Systems
- Monorail conveyor
- Power & Free system
- Circular conveyor
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
Fire Resistance: 2 hours fire rating and 120 min. insulation in accordance with European test standard (EN 1366-7)
Durability: 100,000 cycles
Proof of Usability: European test report engineering judgement is necessary
ECClos-K
Conveyor Systems
- Power & Free system
- Circular conveyor
Fire Resistance: 2 hours fire rating and 120 min. insulation in accordance with European test standard (EN 1366-7)
Durability: 10,000 cycles
Proof of Usability: European test report engineering judgement is necessary
Ecotube
90 minutes fire rating and 90 minutes insulation. Engineering judgement is necessary.
Issue
The closing element, which is permanently in the conveyor stream, can be damaged or contaminated by abrasive goods being transported through the conveyor system. Therefore a reliable closure of the system in case of fire cannot be assured. When transporting sustained fibres through the conveyor some of these fibers get stuck and deposited at the dampers blade, so that the closing process is inhibited.
Customer benefits
- Release by fire detection elements
- During use, connection pipes and pipe liner are congruent – therefore no sedimentation and no abrasion occurs
- 90 minutes fire rating and 90 minutes insulation. As an option we offer a closing process within split seconds by using special pneumatic devices.
- Applicable for over- and negative pressure, always clean by using compatible sealings.
Omnitube
2 hours fire rating and 120 minutes insulation. Engineering judgement is necessary.
Issue
The closure of conveyed goods at a continuous high temperature becomes defective within a very short time.
Customer benefits
- Round or square cross section, no interference of the standard conveyor function
- Different temperature classifications up to 1,300 degrees Fahrenheit, applicable for exhaust systems
Omnicompact
2 hours fire rating and 120 minutes insulation
Conveyor Systems
- Interrupted conveyor systems
- Separable conveyor systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
- Continuous traveling carriages
Fire Resistance: 2 hours fire rating and 120 min. insulation in accordance with European test standard (EN 1634-1)
Durability: 10,000 cycles
Proof of Usability: German approval (90 minutes insulation), European test report. Engineering judgement is necessary.
Isogate
Conveyor Systems
- Continuous overhead conveyor
- Interrupted conveyor systems
- Separable conveyor systems
- Continuous roller conveyor
- Continuous chain conveyor
Fire Resistance: 90 min. fire rating and 90 min. insulation in accordance with European test standard (EN 1634-1)
Durability: 10,000 cycles
Proof of Usability: German approval (90 minutes insulation), European test report. Engineering judgement is necessary.
Customer Benefits:
- Tested according European test standard
- Average opening velocity of up to 20 in/s
- High numbers of cycles up to 1,000/day
- Veterinary compliant version
Turbocoil
Conveyor Systems
- Interrupted conveyor systems
- Separable conveyor systems
High-speed function: 39 in/s
Smoke and fire resistance: Smoke rated fabric up to 2,000 degrees Fahrenheit
Durability: 2,000,000 cycles (in-house testing) engineering judgement is necessary.
Customer Benefits
- High velocity up to 39 in/s
- Smoke rated fabric up to 2,000 degrees Fahrenheit
- 2,000,000 cycles (in-house testing)
- Preassembled and tested, ready for screwing to the cover on site
Sleeve
90 minute fire rating and 90 minute insulation
Conveyor Systems
- Continuous belt conveyor
- Continuous roller conveyor
- Continuous chain conveyor
- Circular conveyor
Fire Resistance: 90 min. fire rating and 90 min. insulation in accordance with European test standard (EN 1634-1)
Durability: not necessary, no movable parts
Proof of Usability: European test report. Engineering judgement is necessary.
Customer Benefits:
- No clearing of the closing area for non-combustible conveyed goods necessary
- No moving sealing elements
- Small space requirement on the wall plates
- Tested according to European test standards with nonflammable goods
Control Units
Arrest system for fire protection on conveyor system closures with embedded alarms inside the system.
Locking device comprises:
- At least one fire alarm
- A trigger device
- A locking device
- A power supply
Building inspector’s requirements: The international Building Code (IBC) stipulates verification of applicability for fire protection closures. These approvals stipulate a locking device of the systems are to be kept open when in operation. The locking device must be suitable. Its applicability must be verified by means of an approval from the building inspectorate. Approval is based on the guidelines for locking devices by IBC.
CONVEYOR SYSTEM CLOSURES
Stoebich Fire Protection – the world leader* has already developed and established in the market 11 world novelties. Over 35 years, Stoebich successfully completed more than 60 fire tests alone for conveyor system closures in many countries.
Additional Assistance
Should you need additional information please contact an estimator at estimates@ohdpdx.com.
Find Us
What's New?
Fall Maintenance for Garage Doors
The temperatures are still warm and the leaves haven’t started to change color, but the pumpkins and goblins lining store shelves are reminders that fall is here and winter weather isn’t far behind. Winter rain, wind, snow, and ice can cause problems for garage doors...
Reach Us